Installation & Parts ManualV-15, V-30, VS-3, and VS-4 Valveswww.lcmeter.comInstallation: M400-20
10V-15 & V-30 Valves - InstallationBecause of the interaction between the valve and thepreset counter, some adjustment may be needed to thepreset
11VS-3 & VS-4 ValvesVS-3 valves are designed for use on MS-30 and MS-40steel case, positive displacement flowmeters; VS-4valves for use on MS-75 s
12VS-3 & VS-4 Valves - InstallationAccessoriesFlangesFlanges are offered in 3 and 4 inch BSPT and NPT sizesand weld types. Material of constructi
13VS-3 & VS-4 Valves - InstallationRetrofit InstallationsDepending on the existing configuration, adding a VS-3or VS-4 Valve may require modificat
14VS-3 & VS-4 Valves - DisassemblingThe VS-3 & VS-4 Valves are under pressure from thecompression spring. The safest method for opening theva
15VS-3 & VS-4 Valves - ReassemblingFor reassembly, refer to Figures 18 & 19 or the partsbreakdown on Pages 21 & 23.1. Place the O-Ring (It
16Item No. Description Part No.110 Housing 40731124 Valve Cap 43985133 Cup 43529138 Guide 43953140 Bearing (2) 09050260 Inner Bearing (2) 47889270 Sha
17Illustrated Parts Breakdown - V-15 ValvesA-3610 Shown
18Illustrated Parts Breakdown - V-30 ValvesItem No. Description Part No.110 Housing Sub-Assembly 40931124 Valve Cap 43976133 Cup 43528138 Guide 439561
19A-4610 ShownIllustrated Parts Breakdown - V-30 Valves
2Table of ContentsDescription Page NumberGeneral Information ... 2Specifications ...
20Illustrated Parts Breakdown - VS-3 Valves110 Housing Sub-Assembly N/S*124 Cap Sub-Assembly 45533133 Cup 43528138 Machined Guide 45530139 Retainer Ri
21A-36501 ShownIllustrated Parts Breakdown - VS-3 Valves
22Illustrated Parts Breakdown - VS-4 ValvesItem No. Description Part No.110 Housing Sub-Assembly N/S*124 Cap Sub-Assembly 45533133 Cup 43528138 Machin
23A-46501 ShownIllustrated Parts Breakdown - VS-4 Valves
© 2007 Liquid ControlsPub. No. 48854B(02/07)A Unit of IDEX Corporation105 Albrecht DriveLake Bluff, IL 60044-22421.800.458.5262 • 847.295.1050Fax:
3SpecificationsModelCompanionFlangesApplicationClass*A3610 3" 1, 16A3611 3" 1, 3, 14A3612 3" 1, 16A3620 3" 3, 4, 14, 15A3622 3&quo
4V-15 & V-30 ValvesV-15 valves are designed for use on M-15 and M-25positive displacement flowmeters; V-30 valves are for useon M-30, M-40, and M-
5V-15 & V-30 ValvesFlangesFlanges are offered in 3 and 4 inch BSPT and NPT sizesand weld types. Material of construction is aluminum.Teflon, Vito
6V-15 & V-30 Valves - InstallationRetrofit InstallationsDepending on the existing configuration, adding a V-15or V-30 Valve may require modificat
7V-15 & V-30 Valves - InstallationRetrofit Installations (continued)Mount the ball joint extension to the preset ring bythreading the screw into
86. Reposition the valve assembly so that the outlet sideis facing up.7. Remove the two screws (Item 615) that hold the guide(Item 138) and seal in pl
9V-15 & V-30 Valves - InstallationCorrect linkage adjustments avoid hydraulic shock.Hydraulic shock occurs when a volume (mass) of liquidmoving a